Quick Calibration process - HD408 Auto Steer

Follow the steps below for successful Quick Calibration

Go to the “Settings” tab on the left side of the screen and select “Quick Calibration"

  1. Measure your machine and installed autosteer components based on the relevant diagram. Input these parameters. Ensure proper units of measurement are selected (Inches or CM).  Units can be changed in system settings. Accuracy is key!

  2. If the gyro sensor has been installed on the front steering axle, confirm the gyro orientation and enter it. This is essential for proper calibration. If you have chosen not to install the gyro sensor, select “NONE WAS.” (Gyro recommended for use at operational speeds 6 mph +)

  3. General mode should be selected. This is ideal for most operations. 

  4. On the Steering Parts Choice tab, select “Motor 5” when prompted

  5. Drive machine to a flat, open area to complete the “Initialization check”.  Wait 10-15 minutes for the system to restart. Do not touch the screen or move the tractor.

  6. Complete the calibration driving process as prompted. 

  7. Once complete, the monitor will be capable of autosteer operation. The RTK state will remain "Fixed."