Impeller Pump Motor Inspection for the DJI Agras T50 Drone

Inspecting the Pump Motor of the Agras T50

  1. Remove Pump from Tank

    • Take out pump from the bottom of the tank.

    • Inspect all seals.

  2. Detach Pump Module

    • Remove three 2mm screws holding the pump module to the pump motor.

    • Disconnect the pump module.

  3. Inspect Pump Motor

    • Check for corrosion.

    • Look for damage to the protective coating on the motor.

    • Spin the shaft to ensure it moves with the magnetic disc.

  4. Inspect Seals

    • Examine the seal around the shaft.

    • Check the seal around the motor itself.

    • Missing a seal could lead to leaks.

  5. Check for Motor Issues

    • Listen for any grinding noises coming from the motor.
  6. Maintenance Schedule

    • DJI recommends replacing this part after 700 hours of flight.

    • This is part of your monthly inspection.

 

Link to Loom

https://www.loom.com/share/d18278104b514422878286dce9c82992