Impeller Pump/Flow Meter/Centrifugal Motor Low Voltage
Somewhere in the spraying system a short has developed or a wire is not getting proper connection.
1. Trace the issue back to the part that is giving the error.
2. Unplug the centrifugal motors one at a time and see if the error goes away.
a. If the error goes away it is likely an issue with one of the centrifugal motors and or the cable.
3. If you have another spraying tank or a spreader tank go ahead and swap it to this one to see if it is an issue with the drone or the spray tank.
a. If it happens with another tank it more than likely is the Spray Module and Cable Distribution board that needs replaced
b. If it is only with the one tank then you have it down to what is on the tank itself. It could be somewhere in one of the cables or one of the pumps or flow meter causing the issue.
4. If the problem is still present after checking and or replacing the cables then it could be the spraying adapter module.
If the problem still persist after trying all of these solutions please give us a call and we can talk through more possible situations.