J100 Flow Meter Replacement

Here is a detailed step-by-step guide along with an accompanying video.

Video

Step 1: Remove Hex Head Screws 0:00

generated-image-at-00:00:00

  • Use a 2.5mm Allen screwdriver.

  • Carefully remove the hex head screws.


Step 2: Loosen Hose Nuts 0:21

generated-image-at-00:00:21

  • Loosen all four hose nuts.

  • If too tight, use channel locks for assistance.


Step 3: Remove Hoses 0:45

generated-image-at-00:00:45

  • Carefully pop off all hoses.

  • Be cautious when removing screws from the flow meter.


Step 4: Understand Screw Threads and Gaskets 1:01

generated-image-at-00:01:01

  • Note that screws thread through into the tank.

  • Ensure small rubber gaskets are present on the back of the flow meter.


Step 5: Prepare to Reattach Screws 1:14

generated-image-at-00:01:14

  • Insert screws through the flow meter with washers on the front side.


Step 6: Secure Screws with Rubber Washers 1:25

generated-image-at-00:01:25

  • Place rubber washers on the backside of the screws to hold them in place.


Step 7: Unplug from the Tank 1:37

generated-image-at-00:01:37

  • Unplug the flow meter from the tank.

  • Optionally, remove the tank for easier access.


Step 8: Reverse the Process 1:45

generated-image-at-00:01:45

  • Reattach all screws to the new flow meter.

  • Ensure to use washers as previously described.


Step 9: Reattach Hoses and Plug In 2:04

generated-image-at-00:02:04

  • Screw the new flow meter into place.

  • Reattach all hoses and plug the flow meter back in.


Step 10: Contact for Further Questions 2:15

generated-image-at-00:02:15

  • If you have any further questions, reach out to your local dealer.