J150 Troubleshooting

J150 Weight Sensor Issue

This article outlines the steps to take regarding certain weight sensor issues on the J150.

 

  •  Weighing data abnormal, or tank retains over 3 L water after each operation. 
    Steps to solve this problem.

(1. Fully shut down and restart your drone. If the issue persist then continue down the list.

(2. Recalibrate the weight sensor.

(3. Remove the tank and zero the scale. Place a test weight (2-10kg) on each of the for sensors one at a time. Identify which sensor is faulty according to the readings. - replace the faulty sensor.

 

  •  An error is reported for a particular weight sensor.
    Steps to solve this problem.
    (1. Fully shut down and restart your drone. If the issue persist then continue down the list.

    (2. Check if the corresponding connector is connected correctly, and un damaged.

    (3. Try weight calibration, If still not fixed - replace weight sensor.   

     

     