Skip to content
English
  • There are no suggestions because the search field is empty.

Impeller Pump Motor Inspection for the DJI Agras T50 Drone

Inspecting the Pump Motor of the Agras T50

  1. Remove Pump from Tank

    • Take out pump from the bottom of the tank.

    • Inspect all seals.

  2. Detach Pump Module

    • Remove three 2mm screws holding the pump module to the pump motor.

    • Disconnect the pump module.

  3. Inspect Pump Motor

    • Check for corrosion.

    • Look for damage to the protective coating on the motor.

    • Spin the shaft to ensure it moves with the magnetic disc.

  4. Inspect Seals

    • Examine the seal around the shaft.

    • Check the seal around the motor itself.

    • Missing a seal could lead to leaks.

  5. Check for Motor Issues

    • Listen for any grinding noises coming from the motor.
  6. Maintenance Schedule

    • DJI recommends replacing this part after 700 hours of flight.

    • This is part of your monthly inspection.

 

Link to Loom

https://www.loom.com/share/d18278104b514422878286dce9c82992